Floor vibration control considering human-structure interaction

FAN Jian-sheng,Quan Li,LI Quan-wang,NIE Jian-guo
2010-01-01
Abstract:The application of multiple tuned mass dampers (MTMD) in the control of excessive vibration of a long-span floor due to human motions was presented, considering human-structure interaction or not. In the analysis model, each stationary human as well as each TMD, was attached into a single degree of freedom (SDF) system representing a controlled vibration mode of the floor as an SDF system. The coupled motion equation of the human-floor-MTMD system was presented and the acceleration response expressed with non-dimensional values was obtained by using Fourier transformation and the static condensation method. The optimal values of MTMD design parameters (frequency ratios and damping ratios) were detected based on the minimization of the acceleration responses of the floor for various MTMD total mass ratios and floor damping ratios with the genetic algorithm. And then, the comparison of vibration control efficiency between the floor considering human-structure interaction and the one not considering was presented, the recommendations for design of MTMD system adopted to the floor with human-structure interaction were put forward. Additionally, the de-tuning effects of a MTMD system due to variations of floor controlled modal mass, controlled modal frequency and MTMD damping ratios were studied. Finally, the design guide for a MTMD system considering de-tuning effects was developed.
What problem does this paper attempt to address?