Experimental study on charge transfer measurement of electrostatic discharges generated on surface of insulative flexible intermediate bulk container using novel Coulomb meter

Yuki Osada,Mizuki Shoyama,Teruo Suzuki,Kwangseok Choi
DOI: https://doi.org/10.1016/j.jlp.2024.105314
IF: 3.916
2024-07-01
Journal of Loss Prevention in the Process Industries
Abstract:Electrostatic accidents with powders still happen with the use of insulative flexible intermediate bulk containers (FIBCs). This paper deals with the transferred charge amount of the electrostatic discharge from the insulating FIBC surface and/or ungrounded metal using novel Coulomb meter. A conveyor-type test facility including insulative FIBC and about 120 kg of polypropylene powder (about 3 mm) was used in this test. As for the results, brush discharges occurred from the charged insulating FIBC surface, and the maximum value was +108 nC. Although it is difficult to accurately determine the energy of the brush discharge, the risk of ignition of combustible powders is considered low. Spark discharges occurred from the ungrounded metal plate, and the maximum transferred charge was observed to be +306 nC. It should be noted that spark discharges at this value can become an ignition source with some combustible powders.
engineering, chemical
What problem does this paper attempt to address?