Charging potential measurement of floating electrode modeled on the arc shield of vacuum interrupter under AC voltage application

Hideaki Fukuda,Kenta Yamamura,Issei Fujita,Ryutaro Kusa,Yasushi Yamano
DOI: https://doi.org/10.1002/eej.23328
2021-01-21
Electrical Engineering in Japan
Abstract:A charging potential of a floating electrode modeled on vacuum interrupter was measured under unipolar AC voltage application using a surface potential meter. As a result, when a lower voltage was applied to the samples, only an induced potential depending on the electrostatic capacities of the sample and surrounding objects around the sample was measured from the floating electrode. However, in the case of high voltage application, not only induced voltage but also a positive charging potential was observed from the floating electrode which was enough to change the potential of the floating electrode. This is due to the field electron emission from the floating electrode itself.
engineering, electrical & electronic