Self-contained calibration samples and measurements of the thermoelectric figure of merit: A method to improve accuracy

D. Vasilevskiy,S. Turenne,R. A. Masut
DOI: https://doi.org/10.1063/5.0200082
IF: 2.877
2024-03-15
Journal of Applied Physics
Abstract:Despite more than seven decades of active research and development in thermoelectricity, the accurate measurement of the thermoelectric (TE) properties of bulk materials has remained a challenge, mainly because of the strong interrelation between thermal and electrical phenomena. This work highlights practical advancements in methods and instrumentation dedicated to the simultaneous measurements of TE properties such as the Seebeck coefficient (S), the thermal (κ), and electrical (σ) conductivities and the dimensionless TE figure of merit ZT = S2σT/κ. The accuracy of a Harman based approach, as implemented by the ZT-Scanner (TEMTE Inc.), applicable to the simultaneous measurement of the above TE properties, has been made possible by a self-contained calibration procedure, which is based on the availability of two samples of the same homogeneous material having different shape factors. It is of practical importance that this approach provides a simple procedure to obtain the calibration for the figure of merit ZT and the thermal conductivity in the temperature interval from 300 to 720 K. In addition, we show that a simplified Harman setup with no thermocouples attached to the sample can also be used for self-contained calibrated ZT measurements. It is concluded that the implemented steady-state approach decreases the relative error down to 1%–2% for ZT measurements and can be recommended for most applications not involving dynamical behavior. In particular, it is proposed that self-generated calibration samples can critically increase the quality and ease of comparison of TE measurements if they are adopted by the TE community.
physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to improve the accuracy in the measurement of the physical properties of thermoelectric materials. Specifically, the paper focuses on how to more accurately measure the Seebeck coefficient ($S$), thermal conductivity ($\kappa$) and electrical conductivity ($\sigma$) of thermoelectric materials simultaneously through self - contained calibration samples and measurement methods, and then improve the measurement accuracy of the dimensionless thermoelectric figure of merit ($ZT=\frac{S^{2}\sigma T}{\kappa}$). ### Background and Challenges 1. **Measurement Challenges**: The performance evaluation of thermoelectric materials requires precise measurement of their electrical and thermal properties. However, there is a strong interaction between these properties, making it difficult to meet the requirements of electrical and thermal conditions simultaneously during the measurement process. For example, the measurement of electrical properties usually requires isothermal conditions, while the measurement of thermal properties requires adiabatic conditions. 2. **Limitations of Existing Methods**: The currently commonly used measurement method is to perform the measurement of different properties separately, using different instruments to measure different samples. Although this method is reasonable, it will lead to the accumulation of total statistical errors. Especially when different laboratories measure the same sample, the error range can be more than 10%. ### Solutions in the Paper 1. **Self - contained Calibration Method**: The paper proposes a self - contained calibration method based on the Harman method. By using two homogeneous samples with different shape factors, accurate measurement of the thermoelectric figure of merit ($ZT$) and thermal conductivity within the same temperature range (300 to 720K) is achieved. 2. **Simplified Harman Device**: The paper also shows that self - contained calibration $ZT$ measurement can be carried out even in a simplified Harman device without thermocouples attached to the sample. 3. **Reduction of Relative Error**: The paper points out that the implemented steady - state method can reduce the relative error of $ZT$ measurement to 1% - 2%, which is suitable for most applications not involving dynamic behavior. ### Main Contributions 1. **Improvement of Measurement Accuracy**: Through the self - contained calibration method, the accuracy of thermoelectric material performance evaluation is significantly improved. 2. **Simplification of Calibration Process**: A simple method is provided to obtain the calibration of the thermoelectric figure of merit ($ZT$) and thermal conductivity, making the measurement more convenient and reliable. 3. **Promotion Suggestion**: It is recommended that the thermoelectric research community adopt self - generated calibration samples to improve the measurement quality and the convenience of comparison. In conclusion, through proposing an innovative self - contained calibration method, this paper solves the key challenges in the performance measurement of thermoelectric materials and provides important technical support for the research and application of thermoelectric materials.