Liquid Level Measurement and Control in High Temperature and High-pressure Environments of Nuclear Power Plant

Yanjun Hu,Tianxiang Xu,Changxian Gan,Qinglian Zhu,Shengzhi Liu
DOI: https://doi.org/10.1088/1742-6596/2520/1/012039
2023-06-21
Journal of Physics: Conference Series
Abstract:There are many pieces of high-temperature and high-pressure system equipment in nuclear power plants, such as deaerators, high-pressure feedwater heaters, steam-water separation reheaters, etc. The media parameters in these systems and equipment are high and the working conditions are complex. It is necessary to solve the above problems by adopting multi-channel averaging, increasing the slope of the condensing line, and separating the sampling ports of multiple channels. After practical verification, the above solution can effectively solve or reduce the above problems, which can provide a reference for the liquid level measurement and control in subsequent similar high-pressure and high-temperature environments in nuclear power plants.
What problem does this paper attempt to address?