Liquid Collapse Level Monitoring for Nuclear Reactors During Loss of Coolant Accident

LI Shengqiang,BO Hanliang,WANG Wenran,JIANG Shengyao
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.06.021
2009-01-01
Abstract:The coolant level is an important parameter for nuclear reactor cooling systems,especially in loss of coolant accidents(LOCA).The differential pressure characteristics of level meter during such accidents were studied theoriticlly and exeperimentally.The pressure waves and addition pressure drops are found to affect the measurements.The error caused by pressure waves is larger,but the experiments show that the total error will be less than 2.5%,which is acceptable for the loss of coolant accidents.Thus,the differential pressure gauges can provide accurate collapse level data,even during the accidents.
What problem does this paper attempt to address?