Similarity Analysis for Reduced Pressure Test on Depressurization Phase during Pressurized Water Reactor Loss of Coolant Accident

LI Yu-quan,YE Zi-shen,QIN Ben-ke,GU Han-yang
DOI: https://doi.org/10.3969/j.issn.1002-6339.2012.02.017
2012-01-01
Abstract:Integral low pressure test facility is economic and applicable to simulate the transients which occur in a pressurized water reactor coolant system under LOCA accidents.An essential part of low pressure test methodology is the similarity analysis and distortion assessment for depressurization phase.After normalization of equations governing depressurization phase based on two-phase mixture model,this work obtains the similarity criteria through scaling analysis.The similarity criteria kept for test facility will be different under different break scenarios simulated.And the similarity distortion is quantified by the similarity number calculation.The calculation result indicates that the distortion in the depressurization simulation increases with the differential pressure between test facility and prototype.Finally,a scaling calculation is conducted for APEX break test,and the result shows the simulation distortion is essential which can be used for the similarity estimation of the APEX test results.
What problem does this paper attempt to address?