Study on water level sensors in NHR-200 vessel

Wenran Wang,Quansheng Duan,Yueyuan Jiang
1996-01-01
Abstract:It can not meet the demand of nuclear safety to use the level measured in the pressurizer to show the reactor vessel level and it is difficult to monitor the level in the vessel of NHR-200 (200MW nuclear heating reactor) with traditional differential pressure liquidometers. So, a new level sensor which is designed according to the heat transfer difference between water (or liquid) and steam (or gas) and the relationship between the level and the differential temperature is developed. The simulating experiment about the sensor is described. The theoretical calculations and the experimental results show that the sensor is correct in principle, reliable in working properties and feasible in structure. The sensor is suitable for monitoring the level in the NHR-200.