Experimental study on the seismic performance of masonry wall reinforced by cement mortar and polypropylene band

Wenyang Zhao,Qiang Zhou,Quanhuan Min,Lingyu Yang,Baitao Sun,Guquan Song
DOI: https://doi.org/10.1007/s11803-023-2178-8
IF: 2.8
2023-04-25
Earthquake Engineering and Engineering Vibration
Abstract:Since masonry structures are prone to collapse in earthquakes, a novel joint reinforcement method with a polypropylene band (PP-band) and cement mortar (CM) has been put forward. Compared with the common reinforcement methods, this method not only facilitates construction but also ensures lower reinforcement cost. To systematically explore the influence of joint reinforcement on the seismic performance of masonry walls, quasi-static tests were carried out on six specimens with different reinforcement forms. The test results show that the joint action of PP-band and CM can significantly improve the specimen's brittle failure characteristics and enhance the integrity of the specimen after cracking. Compared with the specimen without reinforcement, each of the seismic performance indexes of the joint reinforced specimen had obvious improvement. The maximum increased rate about peak load and ductility of the joint reinforced specimen is 100.6% and 233.4%, respectively.
engineering, civil, geological
What problem does this paper attempt to address?