Experimental Study on Both Sides Strengthening of Low-reinforced Shear Wall

Peng Pan,Kai-lai Deng,Ji-Chao Li,Qi-song Miao,Wen-feng Li,Tao Wang
DOI: https://doi.org/10.3969/j.issn.1002-8412.2013.05.009
2013-01-01
Abstract:A group of reinforced concrete buildings which were constructed during 1970s are still used in Qiansanmen zone of Beijing.The structure form of these buildings is fishbone shear wall.As the buildings were built at an early stage,the concrete strength and the reinforcement ratio are very low,which no longer satisfy current seismic design code.Therefore,strengthening is needed.The strengthening method applied in this study is to complete all the constructed from outside without touching upon the inside of the buildings.To measure the effectiveness of the strengthening method,eight wall specimens,e.g.four unreinforced and four strengthened,are constructed and tested.Quasi-static tests are used and different axial force ratios are considered in the tests.Stiffness,strength,and deformation capacity of the specimen are obtained from the tests,and comparison is conducted between strengthened and unreinforced specimens.The test results show that strengthening from single side can increases the strength of the wall,but can't increase the deformation capacity.
What problem does this paper attempt to address?