Ion beam induced luminescence (IBIL) analysis of europium-activated phosphate glass micro-beads scintillators at clinical carbon beam therapy field

Shun Akiyama,Runa Nakajima,Aika Sasaki,Shigeki Kimura,Kazuya Iiduka,Yuki Akagami,Makoto Sakai,Osamu Hanaizumi,Wataru Kada
DOI: https://doi.org/10.1088/1742-6596/2326/1/012012
2022-11-16
Journal of Physics: Conference Series
Abstract:The possibility of real-time monitoring of clinical carbon beams was investigated by analyzing ion beam induced luminescence (IBIL) using phosphate glass (PG) with a dopant of europium (Eu). Phosphate glass with a silver activator (PG: Ag) is known as a substrate for personal dosimeters. Several trials are being made by utilizing PG: Ag as an in-situ diagnostic tool for the clinical radiation therapy field. However, silvers are not actively responding to the radiation during the irradiation because of their build-up effect. In this study, we introduced a co-activator of europium, which is expected to coexist with silvers and have a scintillator property for real-time response. IBIL was successfully visualized with each bunch of 290 MeV/n from synchrotron under different beam intensity from 6.0×10 6 to 3.0×10 9 (clinical beam condition) counts/spill. IBIL measurement at each position of Bragg peak suggested that developed PG:Ag-beads with Eu co-activators have successfully demonstrated real-time radiation monitoring of clinical carbon beams.
What problem does this paper attempt to address?