Linear Boltzmann equation solver for voxel‐level dosimetry in radiopharmaceutical therapy: Comparison with Monte Carlo and kernel convolution
Gunjan Kayal,Benjamin Van,George Andl,Cheng Tu,Todd Wareing,Scott Wilderman,Justin Mikell,Yuni K. Dewaraja
DOI: https://doi.org/10.1002/mp.16996
IF: 4.506
2024-03-06
Medical Physics
Abstract:Background With recent interest in patient‐specific dosimetry for radiopharmaceutical therapy (RPT) and selective internal radiation therapy (SIRT), an increasing number of voxel‐based algorithms are being evaluated. Monte Carlo (MC) radiation transport, generally considered to be the most accurate among different methods for voxel‐level absorbed dose estimation, can be computationally inefficient for routine clinical use. Purpose This work demonstrates a recently implemented grid‐based linear Boltzmann transport equation (LBTE) solver for fast and accurate voxel‐based dosimetry in RPT and SIRT and benchmarks it against MC. Methods A deterministic LBTE solver (Acuros MRT) was implemented within a commercial RPT dosimetry package (Velocity 4.1). The LBTE is directly discretized using an adaptive mesh refined grid and then the coupled photon‐electron radiation transport is iteratively solved inside specified volumes to estimate radiation doses from both photons and charged particles in heterogeneous media. To evaluate the performance of the LBTE solver for RPT and SIRT applications, 177Lu SPECT/CT, 90Y PET/CT, and 131I SPECT/CT images of phantoms and patients were used. Multiple lesions (2–1052 mL) and normal organs were delineated for each study. Voxel dosimetry was performed with the LBTE solver, dose voxel kernel (DVK) convolution with density correction, and a validated in‐house MC code using the same time‐integrated activity and density maps as input to the different dose engines. The resulting dose maps, difference maps, and dose‐volume‐histogram (DVH) metrics were compared, to assess the voxel‐level agreement. Evaluation of mean absorbed dose included comparison with structure‐level estimates from OLINDA. Results In the phantom inserts/compartments, the LBTE solver versus MC and DVK convolution demonstrated good agreement with mean absorbed dose and DVH metrics agreeing to within 5% except for the D90 and D70 metrics of a very low activity concentration insert of 90Y where the agreement was within 15%. In the patient studies (five patients imaged after 177Lu DOTATATE RPT, five after 90Y SIRT, and two after 131I radioimmunotherapy), in general, there was better agreement between the LBTE solver and MC than between LBTE solver and DVK convolution for mean absorbed dose and voxel‐level evaluations. Across all patients for all three radionuclides, for soft tissue structures (kidney, liver, lesions), the mean absorbed dose estimates from the LBTE solver were in good agreement with those from MC (median difference
radiology, nuclear medicine & medical imaging