Radiation Safety Assessment in Prostate Cancer Treatment: A Predictive Approach for I-125 Brachytherapy

Ho-Da Chuang,Yu-Hung Lin,Chin-Hsiung Lin,Yuan-Chun Lai,Chin-Hui Wu,Shih-Ming Hsu
DOI: https://doi.org/10.3390/cancers16101790
2024-05-08
Cancers
Abstract:This study uses Monte Carlo simulation and experimental measurements to develop a predictive model for estimating the external dose rate associated with permanent radioactive source implantation in prostate cancer patients. The objective is to estimate the accuracy of the patient's external dose rate measurement. First, I-125 radioactive sources were implanted into Mylar window water phantoms to simulate the permanent implantation of these sources in patients. Water phantom experimental measurement was combined with Monte Carlo simulation to develop predictive equations, whose performance was verified against external clinical data. The model's accuracy in predicting the external dose rate in patients with permanently implanted I-125 radioactive sources was high (R2 = 0.999). A comparative analysis of the experimental measurements and the Monte Carlo simulations revealed that the maximum discrepancy between the measured and calculated values for the water phantom was less than 5.00%. The model is practical for radiation safety assessments, enabling the evaluation of radiation exposure risks to individuals around patients with permanently implanted I-125 radioactive sources.
oncology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to accurately assess and predict the radiation dose rate in the patient's surrounding environment when using I - 125 permanent radioactive source implantation in the treatment of prostate cancer, so as to ensure compliance with radiation safety guidelines. Specifically, the research objectives are: 1. **Verify the accuracy of measurement and Monte Carlo simulation**: Through experimental measurement and Monte Carlo simulation, verify the accuracy between the measured value and the simulated value of the environmental dose equivalent \(H^*(10)\) outside the water phantom. 2. **Develop a prediction model**: Based on the results of Monte Carlo simulation, develop a set of equation models for predicting the effective dose of the patient's family members or the public after the patient is implanted with a radioactive source. ### Research Background - **Prostate cancer treatment**: Prostate cancer is one of the most common cancers in men. Treatment methods include low - dose - rate (LDR) permanent implant brachytherapy, high - dose - rate (HDR) temporary brachytherapy, external beam radiotherapy (EBRT) and radical prostatectomy (RP). - **I - 125 permanent implant brachytherapy**: The I - 125 radioisotope is often used for permanent implant treatment of local prostate cancer, which can significantly reduce the dose outside the implant area, protect at - risk organs such as the rectum and bladder, reduce side effects, and enable patients to recover more quickly. - **Radiation safety assessment**: After implanting a radioactive source, it is necessary to assess the radiation exposure dose of the people around the patient to ensure that it complies with the recommended standards of the International Commission on Radiological Protection (ICRP), the National Council on Radiation Protection and Measurements (NCRP) and the United States Nuclear Regulatory Commission (NRC). For example, the effective dose of caregivers should not exceed 5 mSv/year, and the effective dose of the public should not exceed 1 mSv/year. ### Research Methods - **Experimental measurement**: Use 30 I - 125 radioactive sources and place them in a Mylar - windowed water phantom to measure the environmental dose equivalent \(H^*(10)\) at different distances. - **Monte Carlo simulation**: Use the PHITS code for simulation. The simulation geometric conditions are consistent with the actual measurement conditions to construct a prediction model. - **Clinical data verification**: Use the clinical data of 21 patients implanted with I - 125 radioactive sources to verify the accuracy of the prediction model. ### Main Results - **Model accuracy**: The maximum difference between the predicted value of \(H^*(10)\) at different distances by the prediction model and the actual measured value is less than 5.00%, and the \(R^2\) value of the model is as high as 0.999. - **Clinical verification**: The differences between the measured values and the predicted values of \(H^*(10)\) at 0 cm, 30 cm and 100 cm are all within 5.00%. ### Conclusion The prediction model in this study can accurately predict the radiation dose rate in the surrounding environment of prostate cancer patients implanted with I - 125 radioactive sources, with an error of less than 10%. This model is helpful for radiation safety assessment, ensuring that the radiation exposure doses of the patient's family members and the public meet the ALARA standard, and thus effectively guiding the radiation protection measures for prostate brachytherapy patients.