Failure Evaluation of a SiC/SiC Ceramic Matrix Composite During In-Situ Loading Using Micro X-ray Computed Tomography

John Thornton,Benedicta D. Arhatari,Mitchell Sesso,Chris Wood,Matthew Zonneveldt,Sun Yung Kim,Justin A. Kimpton,Chris Hall
DOI: https://doi.org/10.1017/S1431927619000187
IF: 4.0991
2019-10-07
Microscopy and Microanalysis
Abstract:In this study, we have examined ceramic matrix composites with silicon carbide fibers in a melt-infiltrated silicon carbide matrix (SiC/SiC). We subjected samples to tensile loads while collecting micro X-ray computed tomography images. The results showed the expected crack slowing mechanisms and lower resistance to crack propagation where the fibers ran parallel and perpendicular to the applied load respectively. Cracking was shown to initiate not only from the surface but also from silicon inclusions. Post heat-treated samples showed longer fiber pull-out than the pristine samples, which was incompatible with previously proposed mechanisms. Evidence for oxidation was identified and new mechanisms based on oxidation or an oxidation assisted boron nitride phase transformation was therefore proposed to explain the long pull-out. The role of oxidation emphasizes the necessity of applying oxidation resistant coatings on SiC/SiC.
materials science, multidisciplinary,microscopy
What problem does this paper attempt to address?