The Application of Ultrasonics to Electroplating with a View to Reducing Hydrogen Embrittlement

J. W. Mee
DOI: https://doi.org/10.1080/00202967.1963.11869874
1963-01-01
Transactions of the IMF
Abstract:The effect of ultrasonic agitation of acid pickling baths and a cadmium cyanide plating bath on the ductility of high tensile steel wire and strip has been measured by slow bend tests and by torsional ductility tests. Hardened and tempered 0·70 and 0·94% carbon steel strip with tensile strengths of 100 and 130 ton/in2* respectively, cold-rolled 0·67% carbon steel strip of 120 ton/in2 tensile strength and hardened and tempered 0·65% carbon steel wire have been less embrittled by hydrogen absorbed during pickling and cadmium plating when ultrasonic agitation has been employed. With one batch of hardened and tempered strip, ultrasonic agitation during plating resulted in complete prevention of hydrogen embrittlement, but other batches contained slight amounts of embrittlement, although much less than if no ultrasonic agitation had been employed.