Experimental study of the irreversible pressure loss coefficient at reduced T-junction with flat tube

Wanjin Bai,Jiumin Xiao,Zhipeng Ru,Long Chen,Xiaoxiao Xu
DOI: https://doi.org/10.1007/s10973-020-09537-7
IF: 4.755
2020-03-21
Journal of Thermal Analysis and Calorimetry
Abstract:The pressure drop is one of the most important factors leading to the distribution of refrigerant in the micro-channel heat exchanger. The main objective of this work was to explore the irreversible pressure loss coefficient of single flow at reduced T-junction with flat tube. The reduced T-junction is placed horizontally with inner diameter of 31.11 mm and the flat tube cross section of 25.4 mm × 2.0 mm. The experiment is carried out using water and R134a as working fluids. Contradictory to traditional T-junction with circular branch tube, this experimental result showed that not only the irreversible pressure loss coefficient of the flat tube is related to the flow separation ratio, but also the Reynolds number upstream of the header when the branch is opened. Under the condition of fixed flow separation ratio, the irreversible pressure loss coefficient decreases with increase in Reynolds number upstream of the header. The irreversible pressure loss coefficients of the single-phase flow are proposed under the conditions of the bypass both closed and opened.
chemistry, physical, analytical,thermodynamics
What problem does this paper attempt to address?