Effects of Deep Cryogenic Treatment on the Microstructure and Properties of Rolled Cu Foil

Zhichao Dong,Xiangyu Fei,Benkui Gong,Xinyu Zhao,Jiwei Nie
DOI: https://doi.org/10.3390/ma14195498
IF: 3.4
2021-09-23
Materials
Abstract:The development of fifth-generation (5G) communication and wearable electronics generates higher requirements for the mechanical properties of copper foil. Higher mechanical properties and lower resistance are required for flexible copper-clad laminate and high-frequency and high-speed Cu foil. Deep cryogenic treatment (DCT), as a post-treatment method, has many advantages, such as low cost and ease of operation. However, less attention has been paid to the impact of DCT on rolled Cu foil. In this study, the effects of DCT on the microstructure and mechanical properties of rolled Cu foil were investigated. The results show that as the treatment time increased, the tensile strength and hardness first increased and then decreased, reaching a peak value of 394.06 MPa and 1.47 GPa at 12 h. The mechanical property improvement of rolled Cu foil was due to the grain refinement and the increase of dislocation density. The dislocation density of rolled Cu foil after a DCT time of 12 h was determined to have a peak value of 4.3798 × 1015 m−2. The dislocation density increased by 19% and the grain size decreased by 12% after 12 h DCT.
materials science, multidisciplinary,chemistry, physical,physics, applied, condensed matter,metallurgy & metallurgical engineering