Experimental Study on Carbon Capture Performance of Polyimide Hollow Fiber Membrane in Post-combustion Process

Liu Yang,Yanchi Jiang,Juan Yu,Ziqi Zhao,Mengchuan Jia,Aiwei Mu
DOI: https://doi.org/10.1007/978-981-16-1657-0_48
2021-09-30
Abstract:Carbon capture and storage (CCS) technology is effective in mitigating the negative effect of the greenhouse gases. At the same time, membrane-based technology for the capture of CO2 has attracted worldwide attention. In this paper, an experimental study on the carbon capture performance of polyimide (PI) hollow fiber membrane in post-combustion process is carried out to analyze the PI membrane system separation performance of single-stage and two-stage membrane separation methods under different pressure, temperature and gas flow rate conditions. For single-stage membrane separation system, increasing feed gas pressure, feed gas temperature and gas flow rate is beneficial to enhance membrane CO2 permeability. For the two-stage membrane separation system, the feed gas pressure of the first/the second stage pressure, as well as the gas flow rate, can effectively influence the CO2 concentration on permeate side, which can reach up to 91.01%. Furthermore, the two-stage method has 40–60% higher CO2 concentration than single-stage method due to the additional membrane stage.
What problem does this paper attempt to address?