Large-dynamic-range fiber loop ringdown strain sensor using Frequency-shifted Interferometry

Chunfu Cheng,Jiaxuan Chen,Zehao Chen,Yiwen Ou
DOI: https://doi.org/10.1007/s11082-021-02962-4
IF: 3
2021-06-01
Optical and Quantum Electronics
Abstract:A fiber loop ringdown (FLRD) sensor combined with frequency-shifted interferometry (FSI) for large strain measurement was proposed and experimentally demonstrated. The FSI technique was employed to realize the space-domain FLRD sensing in which only continuous-wave light source and slow detection were required, and thus the sensing system cost were greatly reduced. A tapered multimode fiber was used as the sensor head for large strain measurement. By measuring the ringdown distance, the strain was monitored and a high strain sensitivity of 0.34 km<sup>−1</sup> mε<sup>−1</sup> was obtained, corresponding to a strain detection limit of 48.2 μɛ. As a benefit from good mechanical strength of multimode fiber, a dynamic range of up to 5 mε was achieved. The experimental results support that the proposed FSI-FLRD strain sensor has advantages of low cost, high sensitivity and good stability, which is suitable for health monitoring of concrete structures.
engineering, electrical & electronic,optics,quantum science & technology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop an optical fiber sensor capable of large - strain measurement, especially in view of the problem that traditional strain sensors are difficult to achieve large - strain measurement greater than about 2 mε in practical applications. Specifically: 1. **Requirement for large - strain measurement**: Many existing strain sensors (such as sensors based on fiber Bragg grating (FBG) and Fabry - Perot interferometer (FPI)) have high sensitivity, multi - point measurement capabilities and commercial availability, but in practical applications, especially in scenarios such as concrete structures, they cannot successfully perform large - strain measurement greater than 2 mε. 2. **Limitations of existing technologies**: - Most existing sensors rely on single - mode fiber (SMF), which has low mechanical strength and limits the strain measurement range. - Some methods attempting to increase the measurement range (such as using FBG - FP sensors, phase - shifted terahertz FBG, broadband dual - comb spectroscopy technology and Pound - Drever - Hall technology) are still limited to the range of several hundred micro - strains (με). - These sensors usually rely on expensive optical spectrum analyzers (OSA), resulting in high costs and being easily affected by the light - power fluctuations of the light source. 3. **Solutions proposed in this paper**: - A new strain sensor combining frequency - shift interferometry (FSI) and fiber - loop - cavity ring - down spectroscopy (FLRD) techniques is proposed. - A section of multimode fiber (MMF) is used as the sensor head, and the strain is monitored by measuring the ring - down distance. - The experimental results show that the sensor achieves a dynamic range of up to 5 mε, a strain sensitivity of 0.34 km⁻¹mε⁻¹, and a detection limit of 48.2 με. - The sensor has the advantages of low cost, easy manufacturing, high sensitivity and high stability, and is suitable for the health monitoring of concrete structures. ### Formula summary The key formulas involved in the paper are as follows: 1. **Expression of the differential interference signal**: \[ \Delta I=\sum_{m = 0}^{\infty}I_m\cos\left(\frac{2\pi n(mL + L_0)}{c}f\right) \] where \(m\) is the number of round - trips, \(n\) is the effective refractive index of the fiber, \(c\) is the speed of light in vacuum, \(L\) is the cavity length, \(L_0\) is a constant, \(f\) is the frequency offset generated by the acousto - optic modulator (AOM), \(F_m=\frac{n(mL + L_0)}{c}\) is the oscillation frequency of the sine component, and \(I_m\) is the amplitude of the interference signal. 2. **Exponential decay formula of the interference signal**: \[ I_m = I_0\cdot\exp\left(-\frac{m}{4.34C}\right)=I_0\cdot\exp\left(-\frac{l}{4.34LC}\right) \] where \(I_0\) is the initial intensity, \(l = mL\) is the distance that light propagates in FLRDC, and \(C\) is the cavity loss (in dB) of the entire FLRDC. 3. **Ring - down distance without strain**: \[ d_0=\frac{4.34L}{C_c} \] where \(C_c\) is the empty - cavity loss. 4. **Ring - down distance with strain**: \[ d=\frac{4.34L}{C_c + C_s} \] where \(C_s=\alpha l_f\epsilon\) is the additional loss caused by strain, \(\alpha\) is the attenuation coefficient caused by strain, \(l_f\) is the length of MMF, and \(\epsilon=\frac{\Delta l_f}{l_f}\) is the strain applied to MMF. 5. **Expression of additional loss**: \[ C_s = 4.34L\left(\fra