Abstract:A fiber loop ringdown (FLRD) sensor combined with frequency-shifted interferometry (FSI) for large strain measurement was proposed and experimentally demonstrated. The FSI technique was employed to realize the space-domain FLRD sensing in which only continuous-wave light source and slow detection were required, and thus the sensing system cost were greatly reduced. A tapered multimode fiber was used as the sensor head for large strain measurement. By measuring the ringdown distance, the strain was monitored and a high strain sensitivity of 0.34 km<sup>−1</sup> mε<sup>−1</sup> was obtained, corresponding to a strain detection limit of 48.2 μɛ. As a benefit from good mechanical strength of multimode fiber, a dynamic range of up to 5 mε was achieved. The experimental results support that the proposed FSI-FLRD strain sensor has advantages of low cost, high sensitivity and good stability, which is suitable for health monitoring of concrete structures.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop an optical fiber sensor capable of large - strain measurement, especially in view of the problem that traditional strain sensors are difficult to achieve large - strain measurement greater than about 2 mε in practical applications. Specifically:
1. **Requirement for large - strain measurement**: Many existing strain sensors (such as sensors based on fiber Bragg grating (FBG) and Fabry - Perot interferometer (FPI)) have high sensitivity, multi - point measurement capabilities and commercial availability, but in practical applications, especially in scenarios such as concrete structures, they cannot successfully perform large - strain measurement greater than 2 mε.
2. **Limitations of existing technologies**:
- Most existing sensors rely on single - mode fiber (SMF), which has low mechanical strength and limits the strain measurement range.
- Some methods attempting to increase the measurement range (such as using FBG - FP sensors, phase - shifted terahertz FBG, broadband dual - comb spectroscopy technology and Pound - Drever - Hall technology) are still limited to the range of several hundred micro - strains (με).
- These sensors usually rely on expensive optical spectrum analyzers (OSA), resulting in high costs and being easily affected by the light - power fluctuations of the light source.
3. **Solutions proposed in this paper**:
- A new strain sensor combining frequency - shift interferometry (FSI) and fiber - loop - cavity ring - down spectroscopy (FLRD) techniques is proposed.
- A section of multimode fiber (MMF) is used as the sensor head, and the strain is monitored by measuring the ring - down distance.
- The experimental results show that the sensor achieves a dynamic range of up to 5 mε, a strain sensitivity of 0.34 km⁻¹mε⁻¹, and a detection limit of 48.2 με.
- The sensor has the advantages of low cost, easy manufacturing, high sensitivity and high stability, and is suitable for the health monitoring of concrete structures.
### Formula summary
The key formulas involved in the paper are as follows:
1. **Expression of the differential interference signal**:
\[
\Delta I=\sum_{m = 0}^{\infty}I_m\cos\left(\frac{2\pi n(mL + L_0)}{c}f\right)
\]
where \(m\) is the number of round - trips, \(n\) is the effective refractive index of the fiber, \(c\) is the speed of light in vacuum, \(L\) is the cavity length, \(L_0\) is a constant, \(f\) is the frequency offset generated by the acousto - optic modulator (AOM), \(F_m=\frac{n(mL + L_0)}{c}\) is the oscillation frequency of the sine component, and \(I_m\) is the amplitude of the interference signal.
2. **Exponential decay formula of the interference signal**:
\[
I_m = I_0\cdot\exp\left(-\frac{m}{4.34C}\right)=I_0\cdot\exp\left(-\frac{l}{4.34LC}\right)
\]
where \(I_0\) is the initial intensity, \(l = mL\) is the distance that light propagates in FLRDC, and \(C\) is the cavity loss (in dB) of the entire FLRDC.
3. **Ring - down distance without strain**:
\[
d_0=\frac{4.34L}{C_c}
\]
where \(C_c\) is the empty - cavity loss.
4. **Ring - down distance with strain**:
\[
d=\frac{4.34L}{C_c + C_s}
\]
where \(C_s=\alpha l_f\epsilon\) is the additional loss caused by strain, \(\alpha\) is the attenuation coefficient caused by strain, \(l_f\) is the length of MMF, and \(\epsilon=\frac{\Delta l_f}{l_f}\) is the strain applied to MMF.
5. **Expression of additional loss**:
\[
C_s = 4.34L\left(\fra