Numerical Analysis of CO2 Absorption Characteristics in Industrial Flue Gas Mineralization Spray Tower Reactor

Chao Wang,Mingzhou Liu,Hongliang Liu,Qiulin Yang,Chang-An Zhou,Lei Song,Kui Ma,Hairong Yue
DOI: https://doi.org/10.1016/j.seppur.2024.129051
IF: 8.6
2025-01-01
Separation and Purification Technology
Abstract:The flue gas mineralization spray tower reactor (MSTR) could supply an effective solution for the industrialization of the CO2 2 absorption process. In this study, numerical simulations considering the Euler-Lagrangian method and mineralization reaction kinetics were employed to investigate the flow characteristic and reaction efficiency in an industrial MSTR. Results showed that the simulation results were highly consistent with the industrial data, verifying the reliability of the model. The uneven liquid distribution caused by wall accumulation existed, and most of the flue gas was easily carried downward by slurry, resulting in a large pressure drop at the bottom. In the MSTR, the CO2 2 absorption efficiency was positively correlated with slurry flow rate, spray velocity and spray angle, which negatively correlated with flue gas flow rate, inlet CO2 2 concentration, and slurry size. Among them, it was most sensitive to slurry size due to the effect of mass transfer area. Moreover, four options including two air intake methods of elbow and annular flow, and two internal components of annular baffles and rod banks were analyzed for reactor optimization, and the combination option of annular baffle and rod bank was an effective means to enhance the reaction efficiency at a relatively lower energy consumption in the industrial MSTR.
What problem does this paper attempt to address?