Integral Validation for Two-Fluid Thermal Hydraulic System Analysis Code LOCUST 1.2 Based on LOFT L9-3 Experiment

Zhenyu Feng,Dalin Zhang,Yiwen Chen,Yangchun Pu,Shichang Yun,Sisi Wang,Caihong Xu,Dongyu He,Ting Wang,Wenxi Tian,Suizheng Qiu,Guanghui Su
DOI: https://doi.org/10.1016/j.anucene.2024.110732
IF: 1.9
2024-01-01
Annals of Nuclear Energy
Abstract:CGN has developed a two-fluid thermal-hydraulic system analysis code, LOCUST 1.2. This paper carries out an integral validation of LOCUST 1.2 based on the LOFT L9-3 experiment. First, the facility has been modeled using "node and branch" approach. Second, steady-state calculation is performed to obtain the initial parameters, which shows that critical parameters are within the uncertainty of experimental measurements. Third, transient response is calculated. For primary coolant system, the core power, the temperatures are in good agreement with the experiment, and the pressure has an acceptable deviation after the main steam control valve shutdown. For secondary side of steam generator, the pressure trend is in good agreement with the experiment, and liquid level fits well to experiment before main steam control valve shutdown. As a result, LOCUST 1.2 has the capability to simulate thermal-hydraulic phenomena for reactor primary coolant system and secondary side of steam generator structures and equipment.