Stability analysis of two-phase flow in a low quality natural circulation loop with a lumped parameter model

Zhiwei Zhou
1994-01-01
Abstract:System equations governing thermal-hydraulics were derived from a set of partial differential conservation equations based on thermodynamic equilibrium-homogeneous model by lumped parameter averaging. A high quality ordinary differential equation solver package LSODE was employed to solve the system equations documented in form of ordinary differential equations. The calculation results of the present analysis were compared with the experimental data from a two-phase liquid-vapor flow instability experiment which was designed and carried out for analyzing the characteristics of thermal hydraulics of a 5 MW integral low temperature heating reactor from Tsinghua Univ.. It is concluded that applying a lumped parameter model to analyze two-phase flow density-wave oscillations and the related nonlinear behaviors in a natural circulation loop at low quality is convincing.
What problem does this paper attempt to address?