Noninvasive Beam Diagnosis Based on the TM010 Mode

Chuang-Ye Song,Wen-Hui Huang
DOI: https://doi.org/10.1007/s41365-024-01409-1
2024-01-01
Nuclear Science and Techniques
Abstract:A resonant cavity based on the TM_010 mode is an effective tool for noninvasive beam characterization. This technique has the advantages of a high signal-to-noise ratio, compact structure, and is related to multiple parameters compared with other beam monitors. In this study, high-precision measurements of the bunch charge, arrival time, bunch length, and energy parameters based on the TM_010 mode are discussed. A cavity beam arrival time monitor (BAM) utilizing a phase cavity has been widely used in many facilities. Regarding bunch-length measurements, the influence of the beam energy, beam offset, and longitudinal spectrum on the TM_010 mode are carefully considered to reduce errors, and the theoretical resolution of two cavities with different frequencies is analyzed. Owing to the dependence of the beam velocity of the beam loss factor, this method can also be used for the detection low beam energy using two cavities with the same frequency but different cavity lengths. A set of three cavities with different lengths and frequencies of 1.902 and 11.424 GHz is presented for measuring the four aforementioned parameters.
What problem does this paper attempt to address?