Transverse beam envelope measurements and the limitations of the 3-screen emittance method for space-charge dominated beams

J.G. Power,H. Wang,M.E. Conde,W. Gai,R. Konecny,W. Liu,Z. Yusof
DOI: https://doi.org/10.1016/j.nima.2005.02.034
2005-07-01
Abstract:In its normal mode of operation, the Argonne Wakefield Accelerator Facility uses a high charge (10–100nC), short pulse (3–5ps) drive bunch to excite high-gradient accelerating fields in various slow-wave structures. To generate this bunch, we designed a 1.5cell, L-band, rf photocathode gun with an emittance compensating solenoid to give optimal performance at high charge; it has recently completed commissioning. More recently, we have begun to investigate the possibility of using this gun in a high-brightness, low-charge operating mode, with charge equal to approximately 1nC, for high-precision measurements of wakefields. Two related measurements are reported on in this paper: (1) measurements of the transverse beam envelope are compared to predictions from the beam dynamics code PARMELA; and (2) investigations into the use of a modified 3-screen emittance measurement method that uses a beam envelope model that includes both space-charge and emittance effects. Both measurements were made for the 1nC, 8MeV beam in the drift region directly following the rf photocathode gun.
What problem does this paper attempt to address?