Research on Thermal Hydraulic Behavior of Small-Break LOCAs in AP1000
W. W. Wang,G. H. Su,W. X. Tian,S. Z. Qiu
DOI: https://doi.org/10.1016/j.nucengdes.2013.06.004
IF: 1.7
2013-01-01
Nuclear Engineering and Design
Abstract:As a Generation III+ reactor that received Final Design Approval by U.S. NRC, AP1000 employs a series of nature forces, such as gravity, natural circulation and compressed gas, to enhance plant safety. Although plenty of work has been done around AP600 and its updated version AP1000 both experimentally and theoretically in the past few decades, thermal hydraulic behavior of small break LOCAs in AP1000 has not been fully understood and further studies are still required.In the present study, the response of AP1000 to a spectrum of cold leg small break LOCAs is simulated and analyzed using RELAP5/MOD3.4, including 2-in. break, 4-in. break, 8-in, break as well as 10-in, break which approaches the upper limit size for small break LOCAs in AP1000. Based on the calculation results, it indicates that the passive safety systems employed by AP1000, including CMTs, ACCs, 1RWST, PRHRS and ADS, combine to provide continuous passive safety injection and residual heat removal. During cold leg small break LOCAs, the core uncovery and fuel heat up do not occur. The peak cladding temperatures (PCTs) during the accident process are far below the Appendix K limit value of 1478 K/2200 degrees F and meet the safety criterion. Results show that the accidental consequence can be mitigated effectively and thus the safety of AP1000 during cold leg small break LOCAs is proven. (c) 2013 Elsevier B.V. All rights reserved.