Force and moment analysis of pipe system for double end break loss of coolant accident in primary loop of PWR

Xiwen Zhang,Zhaohui Yao,Feng He,Xuefeng Wang
1997-01-01
Abstract:The loss of coolant accident in the primary loop system of PWR (pressurized water reactor) is a serious accident related to the situation and size of break point. Based on fluid mechanics, this paper described the double end break accident. The pressure and flow of loop system under this accident were obtained by characteristic line method. The force and moment of pipe system were also obtained by control-volume integrating method. All these results are very important for nuclear safety design and PWR plant analysis.