Numerical Simulations on AC Loss of the REBCO Tape under Rotating Magnetic Field
Yuan Wang,Jin Fang,Yusuke Sogabe,Rodney A. Badcock,James G. Storey,Zhenan Jiang
DOI: https://doi.org/10.1109/access.2023.3340731
IF: 3.9
2023-01-01
IEEE Access
Abstract:REBCO coated conductors are exposed to rotating magnetic fields in various high-temperature super conducting (HTS) applications, such as HTS rotating machines and flux pumps. AC loss will begenerated in the conductors when they carry AC current under rotating magnetic fields. We define AC loss in the coated conductors with and without current as total AC loss and magnetization loss, respectively. In this work, total AC loss and magnetization loss, in a REBCO tape under rotating magnetic fields and a perpendicular AC standing wave magnetic field are numerically investigated. We employ a 2D finiteelement method (FEM) based on the T-A formulation, where T and A, are the current and magnetic vectorpotentials, respectively. In the simulations, the external magnetic field amplitude (B-m) is up to 500 mT and the reduced AC current (i=I-t/I-c0) varies from 0.1 to 0.9, where theItandIc0are the amplitude of the transport current and self-field critical current of the conductor, respectively. Two different types of rotatingfields are considered: one is a uniform field with equal amplitudes and phases at each position, and the other being a non-uniform field created by a rotating Halbach array. Different tape widths ranging from4 mm to 40 mm are considered. Interestingly, the simulation results show substantially higher magnetizationloss in the perpendicular standing wave compared to the rotating magnetic fields when B-m is over 100 m T. We attribute the result to the fact that the magnetization loss is propotional to Jc of the conductor at magnetic field amplitudes much greater than the effective penetration magnetic field. Evidently, the instantaneous loss curves of the SW model and RMF-Uniform model at 200 mT exhibited close similarity with evolvingJcvalues of the two models. Furthermore, when B-m is lower than the effective penetrated field, we observea pronounced disparity in magnetization loss of the wider tape between uniform and non-uniform rotating fields. This highlights the importance of considering the effects of non-uniform field distribution, particularlyat lower magnetic field. We further show that total AC loss under the perpendicular standing wave magnetic field remains greater than that under rotating magnetic fields when B-m>100 mT and i<0.5.