Abstract:Complex spatio-temporal couplings (CSTCs) in the large-scale grating compressors of the ultra-intense laser system detrimentally affect the spatial focusing and time domain compression performance of the output pulse. Pseudo-lateral shearing interferometry (PLSI) is an innovative method for achieving in-situ measurements of the CSTC wavefront error. This paper discusses various error sources and their effection in PLSI measurement, then optimizes measurement equipment parameters based on Monte Carlo (MC) simulation. The experiments measuring the CSTC wavefront error with PLSI are carried out on Chinese SILEX-II, showing high precision of the PLSI with RMS value of 0.08 λ@632.8 nm. Besides, the measured accuracy of the PLSI is within one standard deviation (STD) of the estimated value, verifying the accuracy of the PLSI measurement error analysis.
optics,physics, applied