A Parametric Study on Cavitation Flow Through Steam Trap Valves under High Pressure Difference

Chao Qiu,Zhi-xin Gao,Zhi Min Jin,Jin-yuan Qian,Bengt Sundén
2019-01-01
Abstract:Steam trap valves are mainly used in thermal power systems to pour out condensate water and keep steam inside. While flowingthrough steam trap valves, the condensate water is easy to reach cavitation, which may cause serious damage to the pipingsystem. In this paper, in order to suppress cavitation inside steam trap valves, effects of valve body geometrical parametersincluding orifice diameter, installation angle and the thickness of the cage are investigated by using a cavitation model. Thepressure, velocity and steam volume fraction distribution inside valves are analyzed and compared in different geometricalparameters. The total vapor volumes are also predicted and compared. The results show that geometrical parameters have asignificant influence on the cavitation distribution and vapor volume. The optimal combination of these three parameters tosuppress cavitation are found and verified. The work is of significance for the optimization design of steam trap valves. (Less)
What problem does this paper attempt to address?