Parametric Study on Fluid Dynamics of Pilot-Control Angle Globe Valve

Jin-yuan Qian,Zhi-xin Gao,Bu-zhan Liu,Zhi-jiang Jin
DOI: https://doi.org/10.1115/1.4040037
2018-01-01
Abstract:Globe valve is widely used in numerous industries, and its driving energy consumption accounts for high percentages of the whole piping system. In order to figure out novel globe valves with low energy consumption, the pilot control globe valve (PCGV) is proposed, which is made up of a main valve and a pilot valve. By the pressure difference of fluid itself, the opened/closed status of the main valve can be controlled by the pilot valve, which can save driving energy and shorten the response time. In order to fit PCGV in an angle displaced piping system, the pilot control angle globe valve (PCAGV) is developed. In this paper, with validated numerical methods, both steady and transient simulations focusing on the valve core diameter, the single/multi orifices, orifice diameters and their arrangements located on the valve core bottom are presented. The results show that the pressure difference increases with the increase of the valve core diameter and the decrease of the orifice diameter, and large orifice diameters (d > 12 mm) should be avoided in case the valve cannot be opened. As for the multi orifices, it can be treated as a single orifice which having similar cross-sectional area. Meanwhile, the opening time of the main valve also increases with the increase of the valve core diameter correspondingly. Besides, a fitting formula of pressure difference calculation depending on the inlet velocity and the valve core diameter is obtained, which is a power–law relationship.
What problem does this paper attempt to address?