Optimum design of piloted large flow and high speed onoff valve

DENG Ye-min,KONG Xiao-wu,QIU Min-xiu,WEI Jian-hua
2010-01-01
Abstract:This paper uses the two-stage driving and asymmetric optimization design method,takes the three-way ball valve as the pilot stage and the three-way slide valve as the main stage,the coupling between pilot stage and main state was carried out by a control piston to minimize the demand on the pilot stage control flow by the main stage.Through eliminating the influence on the rapid movement of the main stage valve by the interference factor such as hydrodynamic force and etc.,the rapid action of the high speed onoff valve was allowed.Research result indicates that it is the effective way to improve the dynamic response of the large flowand high speed on-off valve by compensating the hydrodynamic force and using the two-stage driving asymmetric design method.
What problem does this paper attempt to address?