Simulation and Experiment on Static Characteristic of Water Hydraulic Proportional Pressure Relief Valve
ZHANG Zeng-meng,ZHOU Hua,GAO Yua-nan,CHEN Ying-long
DOI: https://doi.org/10.3321/j.issn:0253-9993.2009.11.027
2009-01-01
Abstract:A three-stage water hydraulic proportional pressure relief valve, with ball seat valve as the throttle control pilot stage, was investigated on the static characteristic. An AMESim model was built based on structure and mathematic analysis. The friction at spool, proportional electromagnetic actuator and steady flow force, which cause the valve hysteresis, were analyzed through simulation. The experiment results were also analyzed and compared to simulation results. The investigation shows that the large hysteresis mainly comes from flow force, hysteresis of electromagnetic actuator, and friction. Due to the static and coulomb friction and the structure of lever, the range of the input signal responding to pressure increasing section is narrower than pressure decreasing. The width of hysteresis is larger at low pressure than high pressure. For the reason of nonlinearity and large hysteresis of the valve, closed-loop control will be unstable and large oscillation may be induced. It should be improved through structure optimization or control compensation.