Comparison of forced convective heat transfer between pillar and real foam structure under high Reynolds number
Mingrui Sun,Man Li,Chengzhi Hu,Lei Yang,Yongchen Song,Dawei Tang,Jiafei Zhao
DOI: https://doi.org/10.1016/j.applthermaleng.2020.116130
IF: 6.4
2021-01-01
Applied Thermal Engineering
Abstract:<p>Owing to the complex structure of open-cell foam, Kelvin cell have been widely used to represent foam structures in recent years. In this study, Kelvin cells (pillar model) with different porosities (90%, 95%) and cells per inch (CPI) values (11, 21, 32), as well as foam structures with different porosities (87%, 90%) and 20 pores per inch, were fabricated to investigate forced convective heat transfer in metal foams using computational fluid dynamics (CFD). A comparison between the pillar model and foam structures showed that they had similar changing rule in pressure drops, although the pillar model exhibited 49.2% better comprehensive heat-transfer properties at 90 m/s. The transverse area of the throat and the microstructure of the skeleton had a significant effect on the pressure drop. The heat-transfer behavior can be improved by increasing the CPI and optimizing the joints of the pillar model. Furthermore, the area goodness factors of pillar model with the 95% porosity and 32 CPI is 78.7% better than model with 90% porosity and 11 CPI. Optimization of the transverse area of the throat and the shapes of the skeleton and joints is a potential method for improving the comprehensive heat-transfer performance of Kelvin cells.</p>
energy & fuels,engineering, mechanical,thermodynamics,mechanics