Heat transfer enhancement of a partially serrated twisted finned tube with non-grooving on the leeward side

Hongyu Wei,Tao Cong,Chen Jiang,Wenxue Zhou,Bofeng Bai
DOI: https://doi.org/10.1615/jenhheattransf.2022040235
2022-01-01
Journal of Enhanced Heat Transfer
Abstract:Fin-and-tube heat exchanger is a basic component widely used in many industrial processes such as air cooling and waste heat recovery. To obtain greater comprehensive heat transfer performance, a partially serrated twisted finned tube is proposed. Considering the uneven heat transfer between the windward side and the leeward side, the partially serrated twisted finned tube is serrated on the windward side to enhance the heat transfer and has a non-grooving area on the leeward side. Compared to the fully serrated finned tube, the non-grooving area on the leeward side can increase the heat transfer area and reduce flow resistance. The heat transfer and flow performance experiments on the partially serrated twisted finned tube are carried out to verify the simulation results. The correlations of Nu and f are proposed in the end. Nu of the partially serrated twisted finned tube increase by an average of 14.9% and j/ f(1/3) increases by an average of 9.2% comparing with the annular finned tube with Reynolds number from 5000 to 17,000.