A Thermoelectric Energy Harvesting System Assisted by A Piezoelectric Transducer Achieving 10-mV Cold-Startup and 82.7% Peak Efficiency

Tianqi Lu,Ruizhi Wang,Zhong Tang,Yiwei Zou,Xinling Yue,Yansong Liang,Haoran Gong,Shurui Liu,Zhiyuan Chen,Xun Liu,Junmin Jiang,Bo Zhao,Sijun Du
DOI: https://doi.org/10.1109/tpel.2024.3362366
IF: 5.967
2024-01-01
IEEE Transactions on Power Electronics
Abstract:This article presents a 10 mV-startup-voltage thermoelectric energy harvesting system, assisted by a piezoelectric generator (PEG) as a cold starter. It exploits the fact that when a thermoelectric energy harvesting system is implemented in a place where kinetic energy is also present, the PEG starter can provide a clock signal to start the system. Thanks to the high output impedance of the PEG, the generated clock voltage can easily go over several hundreds of mV, which can be used to drive the boost converter to harvest thermoelectric energy even at an extremely low thermoelectric generator (TEG) voltage. The proposed system was fabricated in a 180-nm BCD process. The measurement results show that the TEG system can start up from the cold state with a TEG voltage as low as 10 mV while maintaining a 63.9 efficiency. The peak power conversion efficiency reaches 83.7 when the TEG voltage is 55 mV.
engineering, electrical & electronic
What problem does this paper attempt to address?