Degradation Analysis of the Core Components of Metal Plate Proton Exchange Membrane Fuel Cell Stack under Dynamic Load Cycles

Tiankuo Chu,Meng Xie,Jia Hao,Zichun Xu,Yantao Li,Daijun Yang,Bing Li,Pingwen Ming,Cunman Zhang
DOI: https://doi.org/10.1016/j.ijhydene.2021.12.068
IF: 7.2
2022-01-01
International Journal of Hydrogen Energy
Abstract:The durability of metal plate proton exchange membrane fuel cell (PEMFC) stack is still an important factor that hinders its large-scale commercial application. In this paper, we have conducted a 1000 h durability test on a 1 kW metal plate PEMFC stack, and explored the degradation of the core components. After 1000 h of dynamic load cycles, the voltage decay percentage of the stack under the current densities of 1000 mA cm-2 is 5.67%. By analyzing the scanning electron microscopy (SEM) images, the surfaces of the metal plates are contaminated locally by organic matter precipitated from the membrane electrode assembly (MEA). The SEM images of the catalyst coated membrane (CCM) cross section indicate that the MEA has undergone severe degradation, including the agglomeration of the catalyst layer, and the thinning and perforation of the PEM. These are the main factors that cause the rapid increase in hydrogen crossover flow rate and performance decay of the PEMFC stack. (c) 2021 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?