EFFECT OF THE NON-LINEAR MAGNETIC FIELDS ON THE EMITTANCE GROWTH IN THE ATF EXTRACTION LINE∗
A. Faus-Golfe,P. Bambade,G. Meur,F. Touzé,Lal M. Woodley,S. Kuroda
Abstract:Since several years, the vertical beam emittance measured in the Extraction Line (EXT) of the Accelerator Test Facility (ATF) at KEK, has been significantly larger than that measured in the Damping Ring (DR) itself. The EXT line that transports the beam to the ATF2 Final Focus beam line has been rebuilt, but the extraction itself remains in most part unchanged, with the extracted beam transported off-axis horizontally in two of the quadrupoles, beyond the linear region for one of them. A few other nearby magnets have also modelled or measured non-linearity. In case of a residual vertical beam displacement, this can result in increased vertical emittance through coupling between the two transverse planes. Tracking studies as well as measurements have been carried out to study this effect and the induced sensitivity of beam optical parameters to the trajectory at injection, in view of deriving tolerances for reproducible and stable operation. EMITTANCE GROWTH IN THE EXTRACTION LINE OF ATF One of the main goals of the ATF2 facility, presently under commissioning, is the establishment of the hardware and beam handling technologies pertaining to transverse focusing of the electron beams nearly to 37 nm, reproducibly and in stabilized conditions. For this, beams with the smallest vertical emittances must both be provided by the ATF DR and preserved throughout the different sections of the optical transport. For several years, the vertical beam emittance measured in the original EXT line, that extracted the beam from the ATF DR, and which at present transports the beam to the ATF2 final focus beam line, has been significantly larger than the emittance measured in the DR itself [1]. One possible contribution that is under study, and is discussed in this paper, is the non-linear magnetic fields in the extraction region experienced by the beam while passing off-axis through magnets of the DR during the extraction process. Simulations including these non-linear fields are presented and compared to observations. Closed orbit bumps in the DR are used to deviate the extraction trajectory and study the effect on the emittance growth. ∗Work supported by FP6 (CARE) contract RII3-CT-2003-506395, FPA 2005-02935 and ANR-06-BLAN-0027 Beam Extraction and Diagnostics The beam is extracted from the DR by means of a first kick, and then passes off-axis through the QM6R and QM7R quadrupoles, nominally at distances of 0.65 and 2.25 cm from their centers, respectively. Then the beam goes through three septum magnets, BS1X, BS2X and BS3X, which complete the extraction. After the extraction, there is a dispersion suppression section, and the beam then goes through a horizontal dispersion-free zone, where five wire scanners are located in order to allow emittance measurements. At the time of this study, the betatron phase advances between the wire scanners could not be fully optimized to enable reliable emittance reconstruction. A complementary quadrupole scanning technique was also available, but because of practical constraints it could not be used easily during the shifts when trajectory bumps were applied [2]. An alternative method consisted in using an Optical Transition Radiation (OTR) monitor installed just after the septum magnets at a location such that it imaged the beam angular spread out of QM7R with little influence from the beam size in QM7R, thus representing the growth in projected emittance from non-linearities in QM7R quite well. This allowed faster and more reliable results since the measured changes in vertical beam size at this location were well correlated with the emittance growth [3], and because the bumps did not need to be closed in the extraction line during the measurements. NON-LINEAR MAGNETIC FIELDS IN THE EXTRACTION REGION In order to quantify the effect of the non-linearity of the magnetic field on the extracted beam, a detailed study of the field maps of the magnets involved in the extraction has been done with the finite element Poisson solver PRIAM [4], from the geometry of these magnets. The obtained field maps have been fitted by a polynomial function in order to get a continuous representation. The results, described in [5], are compatible with those found using the code POISSON [6]. The fit was done by a development in integer series of the complex variable, with complex coefficients, around a reference point: WE6PFP075 Proceedings of PAC09, Vancouver, BC, Canada 2670 Lepton Accelerators A03 Linear Colliders B(x + iy) = By + iBx ∼ N ∑