Experimental Investigation on the Pressure Response Characteristic of the Gravity Driven Boron Injection System / Experimentelle Untersuchung Zur Druckantwortcharakteristik Eines Gravitationsgetriebenen Boreinspeisesystems

S. Y. Jıang,L. L. Gao,Y.J. Zhang,J. H. Bo
DOI: https://doi.org/10.1515/kern-2000-655-607
IF: 0.321
2000-01-01
Kerntechnik
Abstract:The gravity driven boron injection system (GDBIS), designed by the Institute of Nuclear Energy Technology (INET) of the Tsinghua University, PR China, is a new type of passive system to be applied in the 200 MW nuclear heating reactor also designed by INET, The purpose of this system is to shutdown the reactor in an emergency, in case the control rods do not operate properly, The pressure response time and the thermal hydraulic performance of the system have been investigated under different initial conditions. The research results for cold (room temperature nitrogen) and hot (mixture of hot steam and nitrogen) operating conditions are presented. Firstly several factors, e. g. the flow resistance character of the steam and liquid lines, and the volume ratio of the upper spaces of reactor and boron injection tank, affect the pressure response time and the thermal hydraulic performance of the system. Secondly, the steam and liquid communication modes, namely, the time and sequence of the action of valves connecting steam and liquid lines, have great influence on the performance of the system. Thirdly, the limited pressure balance time (about 1.5∼2.0 s) can be achieved under cold operating conditions. This investigation shows that GDBIS can be properly used in the 200 MW nuclear heating reactor.
What problem does this paper attempt to address?