Characteristics of using a jet-pump for a boron injection system in nuclear heating reactors

Haijun Jia,Changwen Ma,Shaorong Wu,Jinhai Bo,Shengyao Jiang,YouJie Zhang
1996-01-01
Abstract:It is a new kind of safety measurement to inject boron liquid into the nuclear reactor during crisis situation. In order to prevent a large amount of coolant from discharging from core a jet-pump was used as safety device of the boron injection system in 5 MW heating reactor. Whether the jet-pump could be used as a safety device of the boron injection system was studied experimentally. The experimental study was performed under the following conditions: pressure 0.1-1.5MPa, temperature 20-198��C, diameter of the work nozzle of the jet pump 1-8 mm, and the charging flow rate 0.1-0.8kg/s. The experiment result shows that the jet pump suitably designed can satisfy the design requirement as a safety device in the boron injection system of the nuclear reactor. The jet pump has been used in the 5MW heating reactor.
What problem does this paper attempt to address?