Research on Multi-Electrode Capacitance Rod Position Measurement Sensor for NHR-200

Yanlin Li,Benke Qin,Hanliang Bo
DOI: https://doi.org/10.1016/j.anucene.2021.108730
IF: 1.9
2021-01-01
Annals of Nuclear Energy
Abstract:ABSTR A C T Rod position measurement sensor is the key equipment of control rod stepping and scram measurement, its accuracy is directly related to the safety and reliability of NHR-200. The nonlinear errors of capacitance rod position measurement sensor (CRPMS) were classified, and the experiments of sensor edge effect and measuring rod eccentricity effect were carried out. The calculation model of CRPMS was established, the results of the model agree well with the experimental results. The relationship between eccentricity error and rod position depth was analyzed, and the design of multiple unequal length helix electrodes CRPMS based on the eccentricity error zeroing method was proposed. The static characteristic experiment of the CRPMS with suspending electrodes was carried out and the model was verified. The edge effect and eccentricity effect nonlinear errors were analyzed by using the model. The results show that the nonlin-ear errors can meet the requirement of rod position measurement accuracy. (c) 2021 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?