Heat Transfer Characteristics Of Ammonia During Flow Boiling In A Horizontal Small Diameter Tube

Yuping Gao,Binfei Zhan,Shuangquan Shao,Hongbo Xu,Changqing Tian
DOI: https://doi.org/10.18462/iir.iccc.2018.0064
2018-01-01
Abstract:The heat exchanger with small diameter tubes can always has a higher heat transfer coefficient. In order to characterize the heat transfer of ammonia in heat exchangers, an experimental apparatus was built up to investigate the heat transfer characteristics of ammonia during flow boiling in a horizontal small diameter tube. In this study, the test section is made of an AISI 316L stainless steel tube with internal diameter of 4 mm. The experiments were performed at the saturation temperatures of -5 degrees C, the mass flux range is from 50 to 100 kg m(-2) s(-1), and the heat flux range is from 7to 21 kW m(-2). The results show that the heat transfer coefficient increases withvapor quality. And the mass flux and heat flux all have positive effect on the heat transfer coefficient, that is, the heat transfer coefficient increases with the rises of mass flux and heat flux.
What problem does this paper attempt to address?