The Application Of The Monitoring, Analysis, And Diagnosis System (Psta-I) In Guangzhou Pumped Storage Power Station (Gpsps)

Fz Feng,Fl Chu,Yy He,Guodan
2000-01-01
Abstract:PSTA-I is a system developed by Tsinghua University cooperated with Guangzhou Pumped Storage Power Station (GPSPS), which can help to monitor, alarm, analyze and diagnose the condition of turbine-generator units. It has been installed on No.1 unit of GPSPS for more than two years, and the system has been identified by the electrical power bureau of Guangdong Province, China. After installation, tremendous of data has been obtained from this system for analyzing. This paper is to introduce some analyzed results of the turbine with this system. In December 1998, during yearly maintenance work made for this turbine, according to the theoretical analysis results, some clearance of the tilting pad guide bearing has been adjusted, Comparing with the practical situation after adjusting the monitored data and the analyzed results are considered to be consistent. In order to introduce PSTA-I system more widely, the introduction part gives a brief description of the system; the second part gives out some examples of the unit recent condition after the data analyzed. Theoretical analyzed results shows that the mechanism of higher pad temperature in upper guide bearing is too large of the pre-load coefficient of the tilting pad bearing which is included in the third part. The end part summarizes the results after its adjustment.
What problem does this paper attempt to address?