The Application of Hydrogenerator Units Monitoring and Analysis System in Beijing SSL Pumped Storage Plant

ZHU Ying,WU Yu-lin,FAN Yu-lin,ZHENG Song-yuan
DOI: https://doi.org/10.3969/j.issn.1000-3983.2007.01.012
2007-01-01
Abstract:the units monitoring and analysis system which was used in Beijing SSL pumped storage plant including the components of the system,the measuring points and the characteristic of the system were introduced in this paper.This system recorded the data of the vibration and run-out before and after the repair,in order to check up the effect of the repair and provide the information to repair.After the repair,the PDA and oil chromatogram systems were installed on unit 3,all of these systems provide the information to decide whether the unit need repair.