Direct Assessment of Solid–liquid Interface Noise in Ion Sensing Using a Differential Method

Da Zhang,Indrek Must,Nathan L. Netzer,Xingxing Xu,Paul Solomon,Shi-Li Zhang,Zhen Zhang
DOI: https://doi.org/10.1063/1.4946857
IF: 4
2016-01-01
Applied Physics Letters
Abstract:This letter presents a microelectrode cell dedicated to direct assessment of the solid–liquid interface noise without recourse to a reference electrode. In the present design, two identical TiN electrodes of various sizes are used for differential measurements in KCl-based electrolytes. Measured noise of the TiN|electrolyte system is found to be of thermal nature. Scaling inversely with electrode area, the noise is concluded to mainly arise from the solid–liquid interface. This noise is comparable to or larger than that of the state-of-the-art MOSFETs. Therefore, its influence cannot be overlooked for the design of future ion sensors.