Improving Phase Retrieval Accuracy of Optical Parallel Plate by Adjusting Exposure Time of CCD

Xu Liu,Yong Liu,Dong Li,Yuhang He,Hongzhen Jiang,Huxiang Zhang,Huan Ren,Liqun Chai,Qihua Zhu,Wanguo Zheng,Qiaofeng Tan
DOI: https://doi.org/10.1088/2040-8986/abf6bb
IF: 2.1
2021-01-01
Journal of Optics
Abstract:A new phase retrieval method is investigated to reconstruct wavefronts of optical parallel plates with the use of a group of diffraction patterns. More specifically, the improved phase retrieval algorithm is realized by converting the measuring plane wave into a spherical wave and by using single or double discrete Fourier transforms to calculate both far- and near-field diffraction propagations, and the accuracy is improved by adjusting the exposure time of the charge-coupled device according to the distance between the focal plane and diffraction plane. Both the theoretical and experimental results are consistent with the results obtained using conventional wavelength-modulated phase-shifting interferometry. The new method opens new doors for realizing wavefront measurement of optical parallel plates with high accuracy, especially for large-aperture parallel plates in inertial confinement fusion laser systems.
What problem does this paper attempt to address?