Numerical simulation and engineering confirmation of hybird SNCR/SCR process in commercial coal-fired boiler

Yinggui Zhou,Baosheng Jin
DOI: https://doi.org/10.3969/j.issn.1001-0505.2016.02.013
2016-01-01
Abstract:To improve the uniform distribution of the reducing agent in the tail flue of the hybrid selective non-catalytic reducing and selective catalytic reducing ( SNCR/SCR) process, numerical simulation was performed for the hybrid SNCR/SCR process in a 300 MW pulverized-coal boiler by using the FLUENT software.The influence of ammonia supplementary position and mixture structure on the distribution of ammonia nitrogen in flue gas was emphatically analyzed.The calculation results agree well with the experimental data.the results reveal that after the SNCR reaction, the concentrations of the reducing agent distribute quite unevenly at the outlet of the reversing chamber. However, with the ammonia supplementary position approaching the reversing angle, the uniform distribution of the reducing agent is improved.Additionally, the distribution can be further optimized by arranging the new hybrid X-mixer device at the inlet of the SCR system.The standard deviation factor for the concentration of the reducing agent in the inlet section of the first layer catalyst of the reactor decreases from 22% to 7.4%. With the combination of the optimized ammonia supplementary position and the new hybrid X-mixer device applied to the industrial boiler, the De-NOx efficiencies of SNCR and SCR process can achieve 35% and 78.4%, respectively, and the total combined De-NOx efficiency of the SNCR/SCR is up to 85.96%, showing a satisfactory denitration performance.
What problem does this paper attempt to address?