Dose-depth Distribution During Sterilization with Electron Radiation

LIU Zhitao,Zhang Huayi,TANG Huaping
DOI: https://doi.org/10.3321/j.issn:1000-0054.2005.06.024
2005-01-01
Abstract:The dose-depth distribution in duplicating paper and polystyrene were calculated using a Monte Carlo N-Particle (MCNP) code to develop a mail sterilization system using radiation from linear electron accelerators. The initial electron energy was assumed to be 4.5 MeV. Factors such as electron energy, radiation angle, paper thickness, and base plates all influence the irradiation effects. The calculated results show that the absorption dose decreases after first increasing. Higher electron energy penetrate deeper into the materials, but the radiation angle does not affect the penetration depth. Base plates can raise the absorption dose near the upper surface of the irradiated material. The calculated results agree well with experimental results, verifying the accuracy of the MCNP simulation.
What problem does this paper attempt to address?