Non-Equilibrium Modeling and Simulation of Double Tank with Four Zones for CMT Water Supply System

Yining ZHANG,Yu JI,Fashe LI,Haochun ZHANG,Yahui WANG
DOI: https://doi.org/10.16112/j.cnki.53-1223/n.2016.03.003
2016-01-01
Abstract:AP1000 nuclear power system belongs to the third generation nuclear power reactor in China’s nucle-ar power development,which is expected to become the main type.The reactor core cooling system is a passive system,and the Core Makeup Tank(CMT)is one of the main types of equipment.Based on mathematical mod-eling and numerical simulation of the full pressure CMT,the reliability of CMT can be verified,and the transient response of the system under normal and accident conditions can also be predicted and evaluated.For a simpli-fied full pressure CMT system,a model consisting of 2 tanks and 4 regions is established,and by using Simulink dynamic simulation method,main parameters of the system,such as the inner pressure and liquid level are simu-lated.The simulation results are consistent with the similar model experiment and simulation results,which pro-vides a theoretical basis for the transient analysis of CMT system.
What problem does this paper attempt to address?