Nb5 N6 Microbolometer for THz Detection

Tu Xuecou,Mao Qingkai,Xu Lei,Sun Zhenlong,Kang Lin,Jin Biaobing,Chen Jian,Wu Peiheng
DOI: https://doi.org/10.13232/j.cnki.jnju.2014.03.004
2014-01-01
Abstract:An important component in terahertz(THz)science and technologies is the detector.In recent years,more attention has been attracted to Nb5 N6 microbolometers,since its high sensitivity,fast response time and easy fabrication.The direct current(dc)responsivity is about 760 V/W at a bias current of 0.19 mA.A typical noise voltage as low as 10 nV/√Hz yields a low noise equivalent power(NEP)of 1.3×10-11 W/√Hz at a modulation fre-quency above 4 kHz.A high-optical responsivity quasioptical THz receiver based on three Nb5 N6 microbolometers connected in series is demonstrated in an actual system.This work could offer another way to develop a large scale focal plane array in silicon with simple technique and low costs.
What problem does this paper attempt to address?