Thermal fatigue failure behavior on Be/Cu joint of ITER first wall after enhanced heat flux test

Dan-hua LIU,Ping-huai WANG,Qian LI,Bo YANG,Fan-ya JIN,Ji-ming CHEN,Shield ITER
DOI: https://doi.org/10.16568/j.0254-6086.201702010
2017-01-01
Abstract:The ITER first wall mock-ups fabricated by joining CuCrZr and 316L(N) stainless steel with explosion welding, machining cooling channel, and then bonding Be tiles on CuCrZr interface with a hot isocratic press technology were subject to high heat flux test, the ultrasonic testing result of mock-up revealed that some larger defects on Be/Cu joint localized on the central area in mock-up. The defects located on Be/Cu interface were inspected by cutting sampling, combined with optical microscope, SEM observation and EDS, analyzing the possible reason what the defects caused by, leading to the first wall manufacturing technology optimization and better material choice.
What problem does this paper attempt to address?